Technical characteristics
- BrandЭлектроника и связь
- Country of manufactureRussia
Description
TIM-191V
Transformers pulse tiny TIM-191V are intended for work in pulse devices of the radio-electronic equipment of industrial function.
TIM transformers work in the pulse mode with impulses lasting from 0,2 to 100 microsec and with an amplitude up to 30 V.
Depending on the transferred impulse duration transformers are subdivided into groups, each of which contains transformers with various number of windings and in coefficient of transformation.
Tiny pulse TIM transformers are produced in vseklimatichesky execution.
Transformers are unified on a design and make a parametrical row which 252 standard ratings enter. They are produced in the protective metal case and are pressurized.
TIM transformers have 9 standard sizes and are produced in two designs:
- execution 1 — on ferrite magnetic conductors TIM1V transformers — TIM105V,
- execution 2 — on permalloyevy magnetic conductors TIM111V transformers — TIM257V.
Isolation resistance between windings in normal climatic conditions — not less than 250 megohms.
Isolation between windings in normal climatic conditions maintains the constant tension of 250 Century without breakdown.
Specifications: TU OYu0.472.045.
Main technical characteristics of TIM transformers:
• The maximum work of duration of an impulse on entrance pulse tension...... from 0,2 to 1500 microsec. In,
• Minimum porosity...... not less than 2,
• Frequency of repetition of an impulse...... from 300 to 100000 Hz,
• Impulse duration...... from 0,2 to 100 microsec,
• Electric durability of isolation...... 250 V,
• Isolation resistance...... 500 megohms,
• Ambient temperature......-60... 105 °C.
Transformers pulse tiny TIM-191V are intended for work in pulse devices of the radio-electronic equipment of industrial function.
TIM transformers work in the pulse mode with impulses lasting from 0,2 to 100 microsec and with an amplitude up to 30 V.
Depending on the transferred impulse duration transformers are subdivided into groups, each of which contains transformers with various number of windings and in coefficient of transformation.
Tiny pulse TIM transformers are produced in vseklimatichesky execution.
Transformers are unified on a design and make a parametrical row which 252 standard ratings enter. They are produced in the protective metal case and are pressurized.
TIM transformers have 9 standard sizes and are produced in two designs:
- execution 1 — on ferrite magnetic conductors TIM1V transformers — TIM105V,
- execution 2 — on permalloyevy magnetic conductors TIM111V transformers — TIM257V.
Isolation resistance between windings in normal climatic conditions — not less than 250 megohms.
Isolation between windings in normal climatic conditions maintains the constant tension of 250 Century without breakdown.
Specifications: TU OYu0.472.045.
Main technical characteristics of TIM transformers:
• The maximum work of duration of an impulse on entrance pulse tension...... from 0,2 to 1500 microsec. In,
• Minimum porosity...... not less than 2,
• Frequency of repetition of an impulse...... from 300 to 100000 Hz,
• Impulse duration...... from 0,2 to 100 microsec,
• Electric durability of isolation...... 250 V,
• Isolation resistance...... 500 megohms,
• Ambient temperature......-60... 105 °C.
Under the order, 14 days.
Similar company products
Contact the seller
Transformer pulse TIM-191V