Currency USD
Aalborg OM-TCi 8.0 - 20 t/h Steam Boiler buy in Houston
Buy Aalborg OM-TCi 8.0 - 20 t/h Steam Boiler
Aalborg OM-TCi 8.0 - 20 t/h Steam Boiler

Aalborg OM-TCi 8.0 - 20 t/h Steam Boiler

In stock
Reconfirm the price with seller
Shipping:
Seller
USA, Houston
(View map)
+1(7 
Display phones
Technical characteristics
  • Boiler typeSteam
Description

General

  • Vertical cylindrical boiler made of mild steel
  • Standard preassembled boiler unit
  • Integrated control panel
  • Ready to install
  • Designed for operation with a rotary cup burner or steam atomizing burner

Design data

Thermal output: up to 14 MW
Steam capacity: 8,000 - 20,000 kg/h
Design pressure: 10 bar(g)

Description

Aalborg OM-TCi (formerly MISSION™ OM-TCi) is a vertical cylindrical steam boiler in the capacity range of 8,000 - 20,000 kg/h. It has been developed based on our well-proven technology and long experience. The best features of the well-known UNEX™ CHB and MISSION™ OM boilers have been incorporated into the new boiler design.

Furnace
Aalborg OM-TCi consists of a large furnace with gas-tight membrane walls. A sufficient number of downcomers ensures safe natural circulation, and adequate furnace dimensioning guarantees good combustion, moderate loading and low material stresses.

Convection part
The cylindrical shell surrounds the smoke tubes. These smoke tubes have enhanced heat transfer features guaranteeing low exhaust gas temperature and thus high efficiency.

Burner
The standard boiler can be delivered with an Aalborg Industries burner with fully automatic operation and control. The burner is designed for a high turndown ratio with complete combustion at low oxygen levels. Alfa Laval Aalborg's KB rotary cup burner or Aalborg KBSA steam atomizing burners are offered based on application or customer preference.

Control system
The burner and boiler can be monitored and regulated by Alfa Laval Aalborg's' own panels such as Aalborg Control, Aalborg Control Touch or the self-diagnostic Aalborg Steam Pilot safety and control systems.

High efficiency and environmental concerns

The upgraded thermal design with optimized flue gas oxygen content ensures a total efficiency of 89-92% depending on boiler load conditions, which is in average 6% above the typical boilers in this capa-city range. This means less fuel consumption and lower CO2 and NOx emission levels. On a 16,000 kg/h boiler operating 5,000 hours at 75% load every year, this means USD 130,000*) saved on fuel cost annually.